Environmental Noise Monitoring PLACID
Environmental Noise Monitoring PLACID
- Available: Please contact
- There are currently no promotions for this product
Hotline: +84 906 988 447
Head Office: Ho Chi Minh City
- Tel: +84 2839 778 269 / 3601 6797
- Email: [email protected]
- Add: 487 Cong Hoa Street, Tan Binh Ward, Ho Chi Minh City, Vietnam
Office: Bac Ninh City
- Tel: +84 222 730 0180
- Email: [email protected]
- Add: 184 Binh Than Street, Vo Cuong Ward, Bac Ninh, Vietnam
-
Technical Counseling
100% Free
-
Free Shipping
For 3.000.000vnd Order
Data is being updated
Overview
Environmental noise monitoring requires instruments that perform reliably over extended deployment periods in harsh outdoor conditions. Temperature extremes, humidity, wind, and precipitation all challenge measurement accuracy. The defensibility of your data depends on demonstrated calibration stability throughout the monitoring period.
Field-ready noise monitoring system for regulatory compliance, construction site monitoring, and environmental impact assessment. Class 1 accuracy with weatherproof housing and remote data access.
Measurement Challenges
- Maintaining calibration accuracy across temperature and humidity extremes
- Wind noise interference and weather protection requirements
- Long-term deployment reliability and data integrity
- Regulatory compliance with stated measurement uncertainty
- Remote monitoring and unattended operation capabilities
PLACID Solutions
- PLACID PMK55-1 outdoor microphone housing with IP55 protection rating
- Class 1 measurement microphones with documented long-term stability
- Windscreen systems designed for omnidirectional wind conditions
- Multi-channel DAQ with remote monitoring capability
- ISO/IEC 17025 accredited calibration with stated uncertainty
Applicable Standards
ISO 1996-1 Description, measurement and assessment of environmental noise — Part 1: Basic quantities and assessment procedures
ISO 1996-2 Description, measurement and assessment of environmental noise — Part 2: Determination of sound pressure levels
IEC 61672-1Electroacoustics — Sound level meters — Part 1: Specifications
ISO 20906 Acoustics — Unattended monitoring of aircraft sound in the vicinity of airports
Typical Specifications Required
- Class 1 frequency weighting accuracy per IEC 61672-1
- Dynamic range covering at least 25 dB(A) to 140 dB(A)
- LAeq, LA10, LA90, LAmax, LAmin statistical descriptors
- 1/3-octave band spectral analysis from 12.5 Hz to 20 kHz
- Temperature operating range of -20 °C to +55 °C
- Outdoor protection rated IP55 or better
- Windscreen insertion loss below 0.5 dB at 1 kHz
Accessories